<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
		xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd"
	xmlns:media="http://search.yahoo.com/mrss/"
>

<channel>
	<title>MRI Metal Detector Blog &#187; cardiac</title>
	<atom:link href="http://mrimetaldetector.com/blog/tag/cardiac/feed/" rel="self" type="application/rss+xml" />
	<link>http://mrimetaldetector.com/blog</link>
	<description>Info on ferromagnetic detection and MRI safety &#38; screening</description>
	<lastBuildDate>Tue, 27 Dec 2011 18:38:54 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
	<copyright>2006-2007 </copyright>
	<managingEditor>tobias.gilk@mednovus.com (MRI Metal Detector Blog)</managingEditor>
	<webMaster>tobias.gilk@mednovus.com (MRI Metal Detector Blog)</webMaster>
	<image>
		<url>http://mrimetaldetector.com/blog/wp-content/plugins/podpress/images/powered_by_podpress.jpg</url>
		<title>MRI Metal Detector Blog</title>
		<link>http://mrimetaldetector.com/blog</link>
		<width>144</width>
		<height>144</height>
	</image>
	<itunes:subtitle></itunes:subtitle>
	<itunes:summary>Info on ferromagnetic detection and MRI safety &#38; screening</itunes:summary>
	<itunes:keywords></itunes:keywords>
	<itunes:category text="Society &#38; Culture" />
	<itunes:author>MRI Metal Detector Blog</itunes:author>
	<itunes:owner>
		<itunes:name>MRI Metal Detector Blog</itunes:name>
		<itunes:email>tobias.gilk@mednovus.com</itunes:email>
	</itunes:owner>
	<itunes:block>no</itunes:block>
	<itunes:explicit>no</itunes:explicit>
	<itunes:image href="http://mrimetaldetector.com/blog/wp-content/plugins/podpress/images/powered_by_podpress_large.jpg" />
		<item>
		<title>PLEASE Don&#8217;t Call It The &#8220;MRI Safe&#8221; Pacemaker&#8230;</title>
		<link>http://mrimetaldetector.com/blog/2011/02/pdont-call-it-the-mri-safe-pacemaker/</link>
		<comments>http://mrimetaldetector.com/blog/2011/02/pdont-call-it-the-mri-safe-pacemaker/#comments</comments>
		<pubDate>Fri, 18 Feb 2011 01:20:54 +0000</pubDate>
		<dc:creator>Tobias Gilk</dc:creator>
				<category><![CDATA[Ferromagnetic Detection for MRI Safety]]></category>
		<category><![CDATA[cardiac]]></category>
		<category><![CDATA[Enrhythm]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[imaging]]></category>
		<category><![CDATA[magnetic]]></category>
		<category><![CDATA[media]]></category>
		<category><![CDATA[Medtronic]]></category>
		<category><![CDATA[MR Conditional]]></category>
		<category><![CDATA[MR Safe]]></category>
		<category><![CDATA[MR Unsafe]]></category>
		<category><![CDATA[MRI]]></category>
		<category><![CDATA[news]]></category>
		<category><![CDATA[pacemaker]]></category>
		<category><![CDATA[reporter]]></category>
		<category><![CDATA[resonance]]></category>
		<category><![CDATA[Revo]]></category>
		<category><![CDATA[safety]]></category>

		<guid isPermaLink="false">http://mrimetaldetector.com/blog/?p=957</guid>
		<description><![CDATA[Call it what it is, the first pacer designed to allow MRI scanning, or the first MR Conditional pacemaker, or even Medtronic's towering achievement (which it is), but PLEASE don't call it the "MRI Safe" pacemaker.]]></description>
			<content:encoded><![CDATA[<p>It&#8217;s almost enough to bring my high school English teacher back from the dead&#8230; me, railing on someone else&#8217;s vocabulary skills. What I&#8217;m talking about here is the new Revo pacemaker (formerly known as Enrhythm) by Medtronic, designed to allow pacemaker patients to receive MRI scans.</p>
<p><span id="more-957"></span></p>
<div class="wp-caption aligncenter" style="width: 452px"><img class=" " src="http://www.wgbh.org/News/Articles/2011/2/9/Images/8123_800x600.jpg" alt="Medtronic Revo Pacemaker" width="442" height="419" /><p class="wp-caption-text">Medtronic Revo Pacemaker (Designed to Permit MRI Scanning)</p></div>
<p>You see, up until the Revo, pacemakers were considered a very potent contraindication to MRI exams. Interference from the MRI acting on the pacemaker could turn the pacer off, turn it into a fairly benign &#8216;asynchronous mode&#8217;, start pacing your heart as if it were a hummingbird&#8217;s at 100&#8242;s of beats per minute, burn cardiac muscle, or drain the pacer&#8217;s battery precipitating an earlier-than-planned replacement.</p>
<p>Some pacemaker patients could still get MRI exams, but you had to be the <em>right</em> kind of pacemaker patient, with the <em>right</em> kind of pacing device, needing the <em>right</em> kind of MRI on the <em>right</em> kind of scanner. Even then, you ought to have had the cardiologist and a code team (to resuscitate you if the MRI and your pacer decided to not cooperate), plus someone to de-program and re-program your pacer. Even with those protections, some insurance companies simply forbid coverage of MRI exams for any pacemaker patient.</p>
<p>Along comes the Medtronic Revo pacemaker. This is the first FDA-approved biostimulation implant that has been specifically designed, from the ground up, to permit MR examinations (though it won&#8217;t be the last). It is not, however, carte blanche for MRI examinations. There are important limitations, or conditions, for its safe use.</p>
<p>There are three designations, each with very specific critera, that an object or medical device can obtain to describe its relative safety in the MR environment, &#8216;MR Safe&#8217;, &#8216;MR Conditional&#8217;, and &#8216;MR Unsafe&#8217;. Given the fact that I just described the Revo as having important limitations, or <em>conditions</em> for safe use, which of these three designations do you think the Revo has earned?</p>
<p>If an object receives the &#8216;MR Safe&#8217; designation, it means that that object would be safe under any allowable MRI conditions. Field strength? <em>Doesn&#8217;t matter.</em> Magnetic spatial gradient? <em>Who cares. </em>Time-varying gradient? <em>No worries, mate. </em>RF deposition? <em>Don&#8217;t worry your pretty little old head.</em> In short, to receive the &#8216;MR Safe&#8217; designation there can not be any restrictions on its use.</p>
<p>So here we are, with a pacemaker that isn&#8217;t &#8216;MR Safe&#8217;, but is being touted in nearly every medical media (or mass media with a health reporter) as the &#8220;MRI Safe pacemaker&#8221;.</p>
<p>[We'll ignore, for this entry, the fact that a company has already copyrighted the phrase "MRI Safe", as well as the fact that this company uses the copyrighted name to describe products that aren't classified as 'MR Safe'.]</p>
<p>For the lay person, my hair-splitting must seem awfully pedantic. The problem is that the technologist who will administer a patient&#8217;s MRI exam gets the bulk of the information about the patient&#8217;s medical history from the patient, himself. If the patient doesn&#8217;t remember the brand-name of the pacemaker (and so many of them seem to forget &#8212; or at least fail to disclose &#8212; that they even have the device, I think remembering the model and manufacturer is very unlikely), they&#8217;re probably likely to remember that this <em>particular</em> one was &#8220;MRI safe&#8221;. Now the technologist, charged with vetting the patient for MRI safety, is being given misleading information about the safety of scanning that patient.</p>
<p>So, my call to healthcare media and reporters is to please&#8230; PLEASE stop calling the Revo the &#8220;MRI Safe&#8221; pacemaker. Call it what it is, the first pacer designed to allow MRI scanning, or the first MR Conditional pacemaker, or even Medtronic&#8217;s towering achievement (which it is).</p>
<address><a href="../2011/02/2011/01/2010/12/2010/12/2010/12/2010/12/2010/10/about-tobias-gilk-editor/" target="_blank"><strong>Tobias Gilk</strong></a>, </address>
<address> </address>
<address> </address>
<address>President &#038; MRI     Safety Director — Mednovus, Inc.</address>
<address>Tobias.Gilk@Mednovus.com</address>
<address><a title="Click for Mednovus.com" href="http://www.mednovus.com/products.html" target="_blank">www.MEDNOVUS.com</a></address>
<address> </address>
<address> </address>
<address> </address>
<address>Sr. Vice President — RAD-Planning.com</address>
<address>TGilk@RAD-Planning.com</address>
<address><a title="Click For RAD-Planning.com" href="http://www.rad-planning.com/" target="_blank">www.RAD-Planning.com</a><br />
</address>
<address> </address>
<p><a href="http://www.twitter.com/tobiasgilk"><img class="alignnone size-full wp-image-852" title="TwitterIcon_32-32" src="http://mrimetaldetector.com/blog/wp-content/uploads/2010/06/TwitterIcon_32-321.gif" alt="Click for Tobias Gilk's Twitter Page" width="32" height="32" /></a><a title="Tobias Gilk on Twitter" href="http://twitter.com/tobiasgilk" target="_blank"> Click here for Tobias’ Twitter Profile</a></p>
]]></content:encoded>
			<wfw:commentRss>http://mrimetaldetector.com/blog/2011/02/pdont-call-it-the-mri-safe-pacemaker/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>CMS Asked To Review MRI For Pacemaker Patient Exclusion</title>
		<link>http://mrimetaldetector.com/blog/2010/07/cms-asked-to-review-mri-for-pacemaker-patient-exclusion/</link>
		<comments>http://mrimetaldetector.com/blog/2010/07/cms-asked-to-review-mri-for-pacemaker-patient-exclusion/#comments</comments>
		<pubDate>Fri, 02 Jul 2010 16:50:47 +0000</pubDate>
		<dc:creator>Tobias Gilk</dc:creator>
				<category><![CDATA[Other MRI Safety]]></category>
		<category><![CDATA[cardiac]]></category>
		<category><![CDATA[CMS]]></category>
		<category><![CDATA[comment]]></category>
		<category><![CDATA[death]]></category>
		<category><![CDATA[defibrillator]]></category>
		<category><![CDATA[device]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[hazard]]></category>
		<category><![CDATA[ICD]]></category>
		<category><![CDATA[imaging]]></category>
		<category><![CDATA[implant]]></category>
		<category><![CDATA[injury]]></category>
		<category><![CDATA[magnetic]]></category>
		<category><![CDATA[Medicaid]]></category>
		<category><![CDATA[Medicare]]></category>
		<category><![CDATA[MRI]]></category>
		<category><![CDATA[National Coverage Determination]]></category>
		<category><![CDATA[NCD]]></category>
		<category><![CDATA[pacemaker]]></category>
		<category><![CDATA[public]]></category>
		<category><![CDATA[radiology]]></category>
		<category><![CDATA[resonance]]></category>
		<category><![CDATA[risk]]></category>
		<category><![CDATA[Russo]]></category>
		<category><![CDATA[safety]]></category>
		<category><![CDATA[Scripps]]></category>

		<guid isPermaLink="false">http://mrimetaldetector.com/blog/?p=854</guid>
		<description><![CDATA[The US Centers for Medicare &#038; Medicaid Services (CMS) have opened a public comment period on a proposal to allow certain MRI scans of pacemaker patients.]]></description>
			<content:encoded><![CDATA[<p>The Centers for Medicare &amp; Medicaid Services (CMS) has opened a brief public comment period on a request to lift reimbursement restrictions on imaging pacemaker patients with pacemakers.</p>
<div id="attachment_807" class="wp-caption aligncenter" style="width: 260px"><img class="size-full wp-image-807" title="pacemaker" src="http://mrimetaldetector.com/blog/wp-content/uploads/2010/02/pacemaker.jpg" alt="" width="250" height="236" /><p class="wp-caption-text">Example of a Pacemaker Pulse-Generator Which Could Present Dangerous Contraindications For MRI Exams</p></div>
<p><span id="more-854"></span>The review has been requested by Robert Russo, MD, with Scripps Research Institute. A copy of Dr. Russo&#8217;s request can be viewed <a title="Click for Dr. Russo's Request Letter (PDF)" href="http://www.cms.gov/DeterminationProcess/downloads/id246.pdf" target="_blank">here</a>.</p>
<p>The public comment period is open through July 28, 2010, and I strongly encourage anyone with questions or concerns about the safety of MR imaging for patients with implanted cardiac devices (Dr. Russo correctly points out that CMS&#8217; restriction fails to speak directly to implanted cardio-defibrillators, or ICD&#8217;s) to offer their comments to CMS.</p>
<p>The full explanation of the current restrictions on MR imaging of pacemaker patients (also aneurysm clip patients, and pregnant patients), as well as the instructions for reviewing other public comments or submitting your own, can be found <a title="Click for CMS's Page on NCD Revision for Pacemakers" href="http://www.cms.gov/mcd/viewtrackingsheet.asp?from2=viewtrackingsheet.asp&amp;id=246&amp;" target="_blank">here</a>.</p>
<address><a href="../2010/06/2010/06/about-tobias-gilk-editor/" target="_blank"><strong>Tobias Gilk</strong></a>, President &amp; MRI    Safety Director</address>
<address>Mednovus, Inc.</address>
<address>Tobias.Gilk@Mednovus.com</address>
<address> <a title="Click for Mednovus.com" href="http://www.mednovus.com/products.html" target="_blank">www.MEDNOVUS.com</a></address>
<p><a href="../wp-content/uploads/2010/06/TwitterIcon_32-321.gif"><img title="TwitterIcon_32-32" src="../wp-content/uploads/2010/06/TwitterIcon_32-321.gif" alt="Click for Tobias Gilk's Twitter Page" width="32" height="32" /></a><a title="Tobias Gilk on Twitter" href="http://twitter.com/tobiasgilk" target="_blank"> Click here for Tobias’ Twitter Profile</a></p>
]]></content:encoded>
			<wfw:commentRss>http://mrimetaldetector.com/blog/2010/07/cms-asked-to-review-mri-for-pacemaker-patient-exclusion/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
	</channel>
</rss>